| Test
Product Performance |
| Abrasion
Resistance |
Taber Abraser
(AS 2105 App D)
Result: 20mg (max) / 100 cycles |
Acids/Alkalis/
Solvents Resistance |
Exposed
(ASTM D 1308)
Result: No discolouration
No Blistering |
| Adhesion |
Natural
well washed exposure
(15 years)
Result: No flaking or peeling |
| Chalking
Resistance |
QUV 2000hrs
(AS 2728)
Rating range: 6-8 |
| Corrosion
Resistance |
Salt spray
1000hrs
(AS 2728 App H1)
Result: Max Chalk rating: 6 |
| Fire Resistance |
Ignitability
Index
(BS 476 Part 5, 1979)
Result: Class O
Fire Propagation
(BS 476 Part 6, 1989)
Result: Class O
Spread of flame
(BS 476 Part 7, 1971)
Result: Class O |
| Humidity
Resistance |
Cleveland
1000hrs (AS 2728)
Result: No more than
Blister
density: 8
Blister
size: A
Undercut from a score: 2 mm max
No loss of adhesion |
|
|
| Guaranteed
Paint properties |
| Hardness |
Pencil (AS
2728)
Result: HB min |
| Adhesion |
Reverse
impact (AS 2728)
Result: 5T min.
Cross hatch
Result: No paint removal |
| Specular
Gloss |
60°
meter (AS 2728)
Result: 20-30% |
|
| Impact
Insulation Class (IIC) |
Laboratory measurement of
IIC of:
GS Multi-Pan Metal roof tile with
| |
40mm thick Rockwool of density
80 kg/m with 40% compression
|
| |
Sisalation Supershied
900 reflective foil |
| |
25x25mm Timber batten |
| |
10mm thick cement board |
| |
Impact Sound Transmission
through floor-ceiling
Assemblies (ASTM E 492-90)
Test by: PSB at NUS
Result: Pass IIC-37
equivalent to a weighted normalised impact
sound pressure level (L'n,w) of 73 as specified
by ISO 717/2-1982 (E) |
|
|
|